Induction Tube Apparatus With 6 Coils, Tube Dimensions (L X D): 1500 X 20 mm, Coil Width: 10 mm, Distance Between Coils: 19 Cm, Due To The Magnet'S Free-Fall Acceleration Caused By Gravity, The Voltage Peaks Increase Proportionally With The Time.
Spectrum Tubes Deuterium, glass tubes approximately 10-1/4in (260mm) long, central capillary portion approximately 3-1/2in to 4in (90-100mm) long with electrodes sealed at both ends and connected to lead wires protected by metal caps.
Highly evacuated electron tube with focusing electron gun and fluorescent screen inclined relative to the beam axis, so that the path of the beam can be seen and the effects of electric and magnetic fields can be studied.
Spectrum Tubes - Sulphur, Length 26Cm, High-Quality Design For Greater Viewing Area, Effectively Demonstrate The Spectral Lines Of Pure Substances, For Use With Spectrum Tube Power Supply
Energy Tube, teaching resource for an array of scientific concepts: open and closed circuits, conductors vs. Insulators, light waves, sound waves,currents, and energy, When a conductor touches both of the electrodes on tube, tube emits a sound and flashing red/green/blue LED lights
Resonance Tube Apparatus, Long version, Material: Acrylic, Mounted on retort stand with clamp and boss, with metal vessel, connecting tubing and spring clip supported on iron ring, Dimension: 120cm
Racing Rings consists of three rods one each of copper, aluminum and PVC, Ring magnet is dropped down the PVC rod, it falls unobstructed, Two metal rods create an induced magnetic field to that adds resistance to the rings travel, metals are different, they fall at different rates
Resistance Substitution Board 33 Ohms - 10M Ohms, Extremely Useful For All Circuit Applications. Great For Electronics Classrooms Or Labs, Or For Use In Circuits Under Design Or In Testing Conditions, Board Dimensions Are 5 X 3.5 X 2 Inches.
Hareft s Apparatus, Mounted on a wooden stand with a scale, comprises a three-limbed glass tube with rubber tubing on the centre. For comparing the densities of liquids by measuring the height of two columns of liquid produced by applying suction, Dimensions 68 x 30 x 15 cm
Boyle's law Horizontal apparatus, A horizontally mounted acrylic tube having a graduated scale (0-300cm3) along one side. A gas tap closes the tube. Pressure gauge is present next to gas tap.
AutoScan Fm Radio Kit, monophonic, two-IC, FM (frequency modulation) receiver designed to receive FM signals in the frequency range (88-108MHz), uses electronic auto-scan, scan with two button switches - one switch scans up, other resets to the start of the tuning position