Vernier® Melt Station
À propos de cet article
Accurately determine the melting temperature of a solid.
Accurate results using built-in RTD over a range of 30°C to 260°C
Accuracy ± 0.31 + 0.0006T, where T is the temperature in Celsius
Resolution 0.10°C
High-quality 6X viewing lens for clear observation of the samples
Innovative, adjustable tilt allows for optimal viewing angle
Cooling fan reduces time between tests
Accuracy ± 0.31 + 0.0006T, where T is the temperature in Celsius
Resolution 0.10°C
High-quality 6X viewing lens for clear observation of the samples
Innovative, adjustable tilt allows for optimal viewing angle
Cooling fan reduces time between tests
Red LED (indicates heating mode)
Blue LED (indicates cooling mode with cooling fan running)
Yellow LED (safety shut off activated)
Blue LED (indicates cooling mode with cooling fan running)
Yellow LED (safety shut off activated)
Connect the Melt Station to a Vernier interface to measure the melting temperature of solid substances.
For educational use only.
Each Melt Station comes with 100 standard capillary tubes. Additional packages of 100 are available.
Détails du produit
Accurately determine the melting temperature of a solid.
Accurate results using built-in RTD over a range of 30°C to 260°C
Accuracy ± 0.31 + 0.0006T, where T is the temperature in Celsius
Resolution 0.10°C
High-quality 6X viewing lens for clear observation of the samples
Innovative, adjustable tilt allows for optimal viewing angle
Cooling fan reduces time between tests
Accuracy ± 0.31 + 0.0006T, where T is the temperature in Celsius
Resolution 0.10°C
High-quality 6X viewing lens for clear observation of the samples
Innovative, adjustable tilt allows for optimal viewing angle
Cooling fan reduces time between tests
Red LED (indicates heating mode)
Blue LED (indicates cooling mode with cooling fan running)
Yellow LED (safety shut off activated)
Blue LED (indicates cooling mode with cooling fan running)
Yellow LED (safety shut off activated)
Connect the Melt Station to a Vernier interface to measure the melting temperature of solid substances.
For educational use only.
Each Melt Station comes with 100 standard capillary tubes. Additional packages of 100 are available.
Documents
Options de la gamme de produits (2)
Informations sur le produit
- DimensionsDisponibilitéPrix
- CA470113-968Vernier melt station (BTA)Base: 13×15×1.5 cm; Body: 9×9×24 cmDirectement du fournisseurEach$1,286.59 / EachDirectement du fournisseur$1,286.59Each$1,286.59Base: 13×15×1.5 cm; Body: 9×9×24 cmNuméro du fournisseur: MLT-BTA
- CA470219-304Capillary tubesDirectement du fournisseurEach$54.19 / EachDirectement du fournisseur$54.19Each$54.19Numéro du fournisseur: MLT-TUBE