Détails du produit

This laboratory benchtop dissolved oxygen meter delivers precision while offering simplicity and versatility in a sleek design. Use your multiparameter meter as a portable, benchtop meter, or mount it on the wall to save space.

  • The large display and it's wide 150° viewing angle provide one of the easiest to read LCDs in the industry
  • Setup and calibrate your meter in no time with as little as a 1 point calibration
  • Great for use in business and educational laboratories worldwide
  • Dissolved oxygen and conductivity electrodes purchased seperately to enable you to measure Conductivity, Total Dissolved Solids (TDS), and pH
  • Your electronic pH meter will automatically recognize each digital electrode, providing sensor type, calibration data, and serial number Advanced pH electrode diagnostics ensure worry-free measurements

Wall Mount-Using the wall mount cradle (included), edge can be placed on a wall, leaving zero footprint on the benchtop space. The cradle has a built-in connector to power the meter and charge its batteries. edge's zero footprint is designed to save you valuable benchtop space.

Cradle and electrode holder - This meter is equipped with a benchtop cradle with an adjustable swivel electrode holder to charge and hold the meter securely in place at the optimum viewing angle.

Data logging - this digital pH meter allows you to store up to 1000 log records of data. Data sets include readings, GLP data, date and time.

DO: 0.00 to 45.00 ppm (mg/L), 0.0 to 300.0%, 0.0 to 50.0 °C (32.0 to 122.0 °F) (Temperature limits will be reduced to actual probe/sensor limits).
Conductivity: 0.00 to 29.99 μs/cm, 3.00 to 29.99 μS/cm, 30.0 to 299.9 μs/cm, 300 to 2999 μs/cm, 3.00 to 29.99 ms/cm, 30.0 to 200.0 ms/cm, up to 500.0 ms/cm.
TDS: 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L absolute TDS ‡ (with 0.80 factor).

Informations de commande: Calibration solutions purchased seperately. pH storage and cleaning solution purchased seperately. pH electrode sold seperately. Replacement pH and Conductivity electrodes sold seperately. Replacement Dissolved Oxygen electrode sold seperately. Calibration solutions, replacement Dissolved Oxygen caps, and replacement electrolyte also sold seperately.

Documents
Spécifications
  • Description:
    Multiparameter dissolved oxygen meter with DO electrode
  • Cat. No.:
    CA470122-476
  • Plage de pH:
    –2.000 to +16.000
  • Résolution du pH:
    0.001 pH, 0.01 pH
  • Précision du pH:
    ±0.01 pH, ±0.002 pH
  • Étalonnage du pH:
    Automatic, up to 3 points (5 points*) calibration, 5 standard (7 standard*) buffers available (1.68*, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45*) and 2 custom buffers*
  • Plage de conductivité:
    0.00 - 29.99 μs/cm, 3.00 - 29.99 μs/cm, 30.0 - 299.9 μs/cm, 300 - 2999 μs/cm, 3.00 - 29.99 ms/cm, 30.0 - 200.0 ms/cm, up to 500.0 ms/cm
  • Résolution de la conductivité:
    0.01 μs/cm, 00.1 μs/cm, 0.01 μs/cm, 0.01 mS/cm, 00.1 mS/cm
  • Précision de conductivité:
    ±1% of reading (±0.05 μs/cm or 1 digit, whichever is greater)
  • Étalonnage de conductivité:
    1 Cell factor calibration; 6 standards available: 84, 1413 μs/cm, 5.00, 12.88, 80.0, 111.8 ms/cm, 1 point offset: 0.00 μs/cm
  • Gamme TDS:
    0.00 - 14.99 ppm (mg/L), 15.0 - 149.9 ppm (mg/L), 150. - 1499. ppm (mg/L), 1.50 - 14.99 g/L, 15.0 - 100.0 g/L, up to 400.0 g/L absolute TDS ‡ (with 0.80 factor)
  • Résolution TDS:
    0.00 - 14.99 ppm (mg/L), 15.0 - 149.9 ppm (mg/L), 150. - 1499. ppm (mg/L), 1.50 - 14.99 g/L, 15.0 - 100.0 g/L, up to 400.0 g/L absolute TDS ‡ (with 0.80 factor)
  • Précision TDS:
    ±1% of reading (±0.03 ppm or 1 digit, whichever is greater)
  • Étalonnage TDS:
    Through EC calibration
  • Précision DO:
    ±1.5% of reading or ±1 digit
  • Étalonnage DO:
    One or two points at 0% (HI 7040) and 100% (water saturated air)
  • Résolution DO:
    0.01 ppm (mg/L); 0.1% saturation
  • Plage de température de fonctionnement:
    0...50 °C (32...122 °F)
  • Plage d'humidité de fonctionnement: