My Account Menu
Canada
Order Entry
Lien pour commandes ContactUsLinkComponent
My Account Menu

Digital Refractometer, Glycols/Coolant, 4 Scales, MDX-603

Résolution: Ethlene glycol (% v/v): 0.1%
Ethlene glycol freezing point: 0.1 °F/0.1 °C
Propylene glycol (% v/v): 0.1%
Propylene glycol freezing point: 0.1 °F/0.1 °C, Accuracy: Ethlene glycol (% v/v): ±0.5%, I17:I19
Ethlene glycol freezing point: ±0.1 °F/±0.5 °C
Propylene glycol (% v/v): ±0.5%
Propylene glycol freezing point: ±1.0 °F/±0.5 °C, Scale Range: Ethlene glycol (% v/v): 0.0 - 65.0%
Ethlene glycol freezing point: −80.0...+32.0 °F/−50.0...+0.0 °C
Propylene glycol (% v/v): 0.0 - 73.0%
Propylene glycol freezing point: −100.0...+32.0 °F

N° de catalogue:   Référence n° ::   76545-896
Digital Refractometer, Glycols/Coolant, 4 Scales, MDX-603
Prix
$918.00
On Order
Date communiquée après la commande
Each

Détails du produit

This digital coolant refractometer measures the concentration and freezing point of the coolants ethylene glycol and propylene glycol. This unit has 4 scales (ethylene glycol, ethylene glycol freeze point, propylene glycol, and propylene glycol freeze point) and comes with a 1-year warranty.

  • Compact and lightweight
  • Removable grip and prism cover for easy cleaning
  • Continuous loop read features (15 reads)
  • Automatic temperature control
  • Zero with distilled water
  • 589.3 nm LED
  • Stainless steel prism well
  • °C/°F switchable temperature display
  • 1 year warranty

The MDX-Series Digital Brix/Sugar Refractometer features IP 65/67 ratings making it ideal for use in the field and in a multitude of environments. Delivering quick, digital accuracy with high-end performance features such as Automatic Temperature Compensation (ATC) and Continuous Loop Average Readings.

Certifications: IP protection class according to DIN EN 60529: IP 67 (for detecting unit) and IP 65 for remainder.

Livraison: Supplied with digital refractometer (Model MDX-603), rubber grip and prism cover, hard shell case with protective lining, disposable pipet, battery and user manual.

Documents
Spécifications
  • Résolution:
    Ethlene glycol (% v/v): 0.1%
    Ethlene glycol freezing point: 0.1 °F/0.1 °C
    Propylene glycol (% v/v): 0.1%
    Propylene glycol freezing point: 0.1 °F/0.1 °C
  • Accuracy:
    Ethlene glycol (% v/v): ±0.5%, I17:I19
    Ethlene glycol freezing point: ±0.1 °F/±0.5 °C
    Propylene glycol (% v/v): ±0.5%
    Propylene glycol freezing point: ±1.0 °F/±0.5 °C
  • Scale Range:
    Ethlene glycol (% v/v): 0.0 - 65.0%
    Ethlene glycol freezing point: −80.0...+32.0 °F/−50.0...+0.0 °C
    Propylene glycol (% v/v): 0.0 - 73.0%
    Propylene glycol freezing point: −100.0...+32.0 °F